ISOMIL - Mineral Insulated Cables
/ Products / ISOMIL-T

ISOMIL-T - Mineral Insulated Thermocouple Cables

In ISOMIL-T the thermoelectric voltages of the thermocouples are in accordance with the basic standard values within the usual tolerance range. For NiCr-Ni the basic values of the thermoelectric voltage are identical in the German and international standards. For both Fe-CuNi (Thermoiron-Thermoconstantan) and Cu-CuNi (Thermocopper-Thermoconstantan) they differ.

These thermocouples are available in ISOMIL-T in accordance with the German Standard Norm DIN 43710 and with the International Thermoelectric Voltage Series (IEC 584).

The limit deviation of the thermocouple voltage is available according the following norm:

• DIN IEC 584-2
• ASTM E 230-93 / ANSI.MC.96.1

Other norms, e.g. GOST on request.


Type denotation ISOMIL-T

Example: The type Denotation 2K2A30 designates a cable coil with 2 cores, inner conductors made of NiCrNi, insulation made of MgO (≥ 97%), the sheath material 1.4541 and an outer diameter of 3 mm.

Number of conductors Inner conductor Insulation Sheath material Outer diameter (1/10 mm)
2 2-cores K NICrNi 1 AI²O³ (97%) A 1.4541  
4 4-cores E NiCr-CuNi 2 MgO (≥ 97%) F 1.4571  
6 6-cores J Fe-CuNi 3 MgO (99,4%) L 2.4816  
8 8-cores T Cu-CuNi   C 2.4851  
  U Cu-CuNi   G 2.4858  
  S PtRh10%-Rh   P 2.4951  
  R PtRh13%-Rh   Q 1.4845  
  N Nicrosil-Nisil   R 1.4301  
      S 1.4404  
      X 1.4876  
NC Incotherm TG

Standard Program ISOMIL-T