ISOMIL - Mineral Insulated Cables
/ Know How / Heating cables - Resistance Correction Factor

Resistance Correction Factor for Heating Cables


Resistance Multiplier for Conductor Materials - Power on

Resistance Multiplier for Conductor Materials - Power on

Pipe Temperature to be maintained (°C / °F)

                           

Resistance Multiplier for Conductor Materials - Power off

Resistance Multiplier for Conductor Materials - Power off

Pipe Temperature to be maintained (°C / °F)

                           

Remarks

Tolerance on conductor resistance is ± 5 % for all 300 volt 2/C cables and 600 volt 1/C cables.

The maximum recommended loading is 200 watts per metre for all 300 volt 2/C cables and 210 watts per metre for all 600 volt 1/C cables.

For pipe tracing, the maximum recommended watts per metre of cable may be reduced to the pipe to maintain or process temperature.

Minimum bend radius is 5 times nominal cable diameter.